Beskrivning
Direktstart med magnetutlösare upp till 15 kWDie kombination motorskyddsbrytare TeSys GV2 med skydd TeSys D garanterar högsta tillförlitlighet, kompakta konstruktioner och enklaste urval.
Direktstart med magnetutlösare upp till 15 kWDie kombination motorskyddsbrytare TeSys GV2 med skydd TeSys D garanterar högsta tillförlitlighet, kompakta konstruktioner och enklaste urval.
- Tillverkarnr.
- LG7K06Q710
- Typ
- LG7K06Q710
- Width
- 175
- Height
- 165
- Depth
- 177
- With transformer
- FALSE
- Rated operation power at AC-3, 400 V
- 2.2
- Number of command positions
- 4
- Number of auxiliary contacts as normally open contact
- 0
- Number of auxiliary contacts as normally closed contact
- 0
- Suitable for emergency stop
- TRUE
- Rated operation current Ie
- 6
- Number of indicator lights
- 0
- Supporting protocol for LON
- FALSE
- Supporting protocol for TCP/IP
- FALSE
- Supporting protocol for ASI
- FALSE
- Supporting protocol for PROFIBUS
- FALSE
- Supporting protocol for CAN
- FALSE
- Supporting protocol for INTERBUS
- FALSE
- Supporting protocol for Modbus
- FALSE
- Supporting protocol for Data-Highway
- FALSE
- Supporting protocol for DeviceNet
- FALSE
- Supporting protocol for SUCONET
- FALSE
- Supporting protocol for other bus systems
- FALSE
- External reset possible
- FALSE
- Suitable for rail mounting
- FALSE
- Degree of protection (IP)
- IP55
- Supporting protocol for SERCOS
- FALSE
- Supporting protocol for INTERBUS-Safety
- FALSE
- Release class
- CLASS 10
- With short-circuit release
- TRUE
- With fuse
- FALSE
- Type of electrical connection of main circuit
- Screw connection
- Type of electrical connection for auxiliary- and control current circuit
- Screw connection
- Supporting protocol for AS-Interface Safety at Work
- FALSE
- Supporting protocol for DeviceNet Safety
- FALSE
- Supporting protocol for EtherNet/IP
- FALSE
- Supporting protocol for Foundation Fieldbus
- FALSE
- Supporting protocol for PROFINET CBA
- FALSE
- Supporting protocol for PROFINET IO
- FALSE
- Supporting protocol for PROFIsafe
- FALSE
- Supporting protocol for SafetyBUS p
- FALSE
- Voltage type for actuating
- AC
- Type of motor starter
- Direct online starter (DOL)
- Rated operation power at AC-3, 230 V, 3-phase
- 1.1
- Rated power, 460 V, 60 Hz, 3-phase
- 3
- Rated operation current at AC-3, 400 V
- 6
- Ambient temperature, upper operating limit
- 40
- Temperature compensated overload protection
- TRUE
- Rated conditional short-circuit current, type 1, 480 Y/277 V
- 50000
- Coordination class according to IEC 60947-4-3
- Class 1
- Typ av produkt
- Direktstarter
Recensioner